SIP Header / Lintel
Panel self-header (box beam) over openings; sizes an inserted lumber/LVL header when the panel can't span.
Validation, assumptions & limitations Download validation report (PDF) ↗
This calculator is verified by 4 independent tests comparing its output against closed-form statics, NDS/SDPWS design-standard values and published worked examples. Full case-by-case results are in the PDF report.
Assumptions
- Tributary gravity load delivered uniformly to the header over the opening; simple-span.
- Box beam = two OSB facings as webs of depth h_b; core/spline ignored (conservative).
- Inserted header is a solid rectangular section of the input width.
Limitations
- Facing E and allowable bending/shear are PRODUCT-SPECIFIC (ESR / AC04).
- End splines and edge lumber that add capacity are neglected.
- Inserted-header sizing reports a required depth and a nominal pick; confirm the actual member's NDS-adjusted capacity.
Results are for preliminary design and must be confirmed by a licensed engineer against the current adopted code and project-specific conditions.