Concrete Column

Tied rectangular column P-M interaction by strain compatibility (ACI 318-19 Ch. 22).

Validated4 independent tests · PDF
Strength design (LRFD): enter factored demands (Pu, Mu, Vu from your load combinations). Results follow ACI 318-19; bar areas use standard ASTM sizes. Confirm detailing (development, spacing, ties) separately.
Code edition
Design diagram — updates live with your inputs

Section

Column section width
Column section depth (bending direction)

Materials

Reinforcement

Distance to longitudinal bar centroid
Total, split equally between two faces

Factored Demands

Compression +
ACI 318-19
Validation, assumptions & limitations Download validation report (PDF) ↗

This calculator is verified by 4 independent tests comparing its output against closed-form statics, NDS/SDPWS design-standard values and published worked examples. Full case-by-case results are in the PDF report.

Assumptions

  • Tied rectangular column; longitudinal bars split equally each face.
  • Uniaxial bending; plane sections, eps_cu = 0.003.
  • Es = 29,000 ksi; standard ASTM bar areas.

Limitations

  • Uniaxial P-M only (no biaxial Bresler check here).
  • Slenderness handled by the separate beam-column tool.
  • Detailing (tie size/spacing, splices) confirmed separately.

Results are for preliminary design and must be confirmed by a licensed engineer against the current adopted code and project-specific conditions.